Bluetooth Continuous Basal Thermometer

A smart and versatile thermometer

monitoring your basal temperature and reminding your ovulation cycle!

Trendy

Lifestyle Design

Features

+

Continuous Monitoring

+

30 Seconds Single Test

+

Reminder

+

Physical Activity

+

Anti-Allergic &

Bio-Toxic Free

+

Mobile APP

+

Ingress Protection 64

+

Bluetooth 4.0

State-of-the-Art Technology

Under-arm readings less than 30 seconds as a single measurement and continuous monitoring around the clock.

 

Unique Interlink Design

A soft & flexible sensing probe extension designed to ensure comfortable attachment, steady Bluetooth connection, and to prevent accidental swallowing.

 

Comprehensive APP

Graphical interpretation of basal temperature and physical activity, analysis of saliva crystallization, reference of potential fertility period, and reminder for morning tests.

 

Thermo Adhesive Pad Traps Body Heat to Assure Accurate

Thermo pad of special ingredient minimizes heat loss via convection and conduction, assuring faster and more accurate measurement. Thermal image shows the colder pad keeps the body heat beneath it.

 

Soft & flexible sensing probe extension design

Stainless SUS 304 Sensing Probe

Comfortable Contact

Food Grade Silicone

Thermo Adhesive Pad

Holder

Usage Method

Two Friendly

Methods to

Wear Thermometer

Mommycare APP

Mobile APP capable of remote control via Bluetooth

Automatic Basal Body Temperature (BBT) determination and friendly reminder for measurements

Synchronization of BBT with saliva crystallization analysis to ensure accurate ovulation simulation

Reference of potential fertility period

Wake up reminder for morning tests

Physical activity recording

Over 8 consecutive hours of result storage & chart analysis

iOS & Android mobile phone compatible

  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  


Technical Specifications

Temperature Measuring Range

Measuring Methodology

 

Resolution

Accuracy

 

 

Transmission Interface

Sensor

 

Indication of Operation

Operating Temperature

Operating Humidity

Operating Atmospheric Pressure

Storage Temperature

Storage Humidity

Power Source

Power Up

Power Consumption

 

 

Auto-Off Time

Material Tangible

Ingress Protection Rating

Dimensions

 

 

 

Weight

 

 

 

 

 

 

 

 

 

 

32.00 ~ 42.90°C (89.60 ~ 109.22°F)

Single measurement - Underarm, <30 seconds, Predictive

Continuous measurement - Underarm

0.01°C / °F

±0.05°C / 0.09°F (35.50 ~ 42.00°C / 95.90°F ~ 107.60°F)

±0.1°C / 0.2°F (32.00 ~ 35.49°C & 42.01 ~ 42.90°C /

                            89.60 ~ 95.88°F & 107.62°F ~ 109.22°F)

BLE single mode, SIG standard SPI, I2C, GPIO, OTA

Thermistor

Acceleration sensor

Visual, green & red dual-color LED, no beeper

5.0 ~ 40.0°C / 41.0  ~ 104.0°F

15% ~ 95% RH non-condensing

70 ~ 106 kPa

-20 ~ 60°C / -4.0 ~ 140.0°F

15% ~ 95% RH non-condensing

CR2032 Lithium-ion battery x 1

Tact switch on the housing and activated by mobile device

Measuring 1.0mA

Transmission 20mA

Standby 6uA

3 minutes ±10 seconds without activation from mobile device

SUS304, PC, PMMA, PBT, Silicone Rubber (ISO10993 compliance)

IP64

Main 40.0 (dia.) x 11.0 (t.) mm

Probe 5.0 (w.) x 3.5 (t.)mm

Probe tip 7.3(dia.) x 3.5(t.)mm

Total length 145mm

18g ±10%

 

 